Peicc Aior Cooler
Product Features
CDB series commercial dual discharge coolers is mainly usedin small operating rooms.
1. Casing: Al-Mg alloy sheet with powder coating RAL9003,strong anti-corrosion performance and light weight Outer drip tray adopts integral hinged structure, easy to clean and operate.
2. Heat exchanger Coil: Copper tubing Φ12,Spacing 38.1x33;Corrugated aluminium fins,fin spacing 4.2mm & 6.4mm.
3. Fans: Axial fans, working temperature -40℃~60℃,fans individually connected to junction box Fan specification Φ350, number from 1 to 4, fan motors are divided into 4-poles and 6-poles to meet different noise requirements.
4. Defrosting: Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting & water plate electric defrosting can also be used.
5. It can meet the requirements of R404A, R507A, R448A, R449A,R134a, R22 and other refrigerants.
Techical Data
|
Model |
KW |
Cooling Area | Fan | Defrost electrical heater | |||||||||
| Air volume(cmh) | Diameter of fans(mm) | Quantity (set) |
Power (w) |
Voltage | Coli (kw) |
Quantity | Coil(W) | Quantity | Total(W) | Voltage (V) |
|||
| DL3.9/20 | 3.9 | 20 | 3400 | 300 | 2 | 164 | (V) | 1600 | 2 | 1600 | 2 | 3200 | 220 |
| DL5.8/30 | 5.8 | 30 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DL7.8/40 | 7.8 | 40 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DL10.7/55 | 10.7 | 55 | 6900 | 350 | 3 | 375 | 220 | 3300 | 2 | 3300 | 2 | 6600 | 220 |
| DL15.5/80 | 15.5 | 80 | 9200 | 350 | 4 | 500 | 380 | 2400 | 2 | 2400 | 2 | 4800 | 380 |
| DL20.3/105 | 20.3 | 105 | 12000 | 400 | 4 | 740 | 380 | 4600 | 2 | 4600 | 2 | 9200 | 380 |
| DL26.2/135 | 26.2 | 135 | 16000 | 450 | 4 | 920 | 380 | 5000 | 2 | 5000 | 2 | 10000 | 380 |
| DL31.0/160 | 31.0 | 160 | 16000 | 450 | 4 | 920 | 380 | 5200 | 2 | 5200 | 2 | 10400 | 380 |
| DL35.9/185 | 35.9 | 185 | 16000 | 450 | 4 | 920 | 380 | 6000 | 2 | 6000 | 2 | 12000 | 380 |
| DL42.6/220 | 42.6 | 220 | 19200 | 450 | 4 | 1000 | 380 | 6400 | 2 | 6400 | 2 | 12800 | 380 |
Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
|
Model |
KW |
Cooling Area | Fan | Defrost electrical heater | |||||||||
| Air volume(cmh) | Diameter of fans(mm) | Quantity (set) |
Power (w) |
Voltage | Coli (kw) |
Quantity | Coil(W) | Quantity | Total(W) | Voltage (V) |
|||
| DD2.7/15 | 2.7 | 15 | 3400 | 300 | 2 | 164 | 220 | 1600 | 2 | 1600 | 2 | 3200 | 220 |
| DD3.9/22 | 3.9 | 22 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DD5.4/30 | 5.4 | 30 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DD7.2/40 | 7.2 | 40 | 6900 | 350 | 3 | 375 | 220 | 3300 | 2 | 3300 | 2 | 6600 | 220 |
| DD10.7/60 | 10.7 | 60 | 9200 | 350 | 4 | 500 | 380 | 2400 | 2 | 2400 | 2 | 4800 | 380 |
| DD14.3/80 | 14.3 | 80 | 12000 | 400 | 4 | 740 | 380 | 4600 | 2 | 4600 | 2 | 9200 | 380 |
| DD17.8/100 | 17.8 | 100 | 16000 | 450 | 4 | 920 | 380 | 5000 | 2 | 5000 | 2 | 10000 | 380 |
| DD21.4/120 | 21.4 | 120 | 16000 | 450 | 4 | 920 | 380 | 5200 | 2 | 5200 | 2 | 10400 | 380 |
| DD25.0/140 | 25.0 | 140 | 16000 | 450 | 4 | 920 | 380 | 6000 | 2 | 6000 | 2 | 12000 | 380 |
| DD28.6/160 | 28.6 | 160 | 19200 | 450 | 4 | 1000 | 380 | 6400 | 2 | 6400 | 2 | 12800 | 380 |
Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
Product display


Installation Dimensions
| MODEL | A | B | C | D | W | E | E1 | N | F | Cycle pipe | Inlet tube connector | Outlet tube connector |
| DL20 DD15 |
940 | 680 | 345 | 730 | 780 | 730 | 365 | 2 | 120 | 12 | 22 | G1" |
| DL30 DD22 |
1240 | 730 | 345 | 780 | 830 | 1030 | 515 | 2 | 120 | 12 | 22 | |
| DL40 DD30 |
1340 | 780 | 345 | 830 | 880 | 1130 | 565 | 2 | 120 | 16 | 28 | |
| DL55 DD40 |
1740 | 780 | 345 | 830 | 880 | 1530 | 510 | 3 | 120 | 16 | 28 | |
| DL80 DD60 |
2330 | 820 | 345 | 870 | 920 | 2030 | 507.5 | 4 | 165 | 16 | 28 | |
| DL105DD80 | 2930 | 870 | 345 | 920 | 970 | 2630 | 657.5 | 4 | 165 | 19 | 32 | |
| DL135DD100 | 2730 | 920 | 445 | 970 | 1020 | 2430 | 607.5 | 4 | 165 | 19 | 32 | |
| DL160DD120 | 2830 | 1020 | 395 | 1070 | 1120 | 2530 | 632.5 | 4 | 165 | 19 | 32 | |
| DL185DD140 | 2830 | 1020 | 445 | 1070 | 1120 | 2530 | 632.5 | 4 | 165 | 22 | 35 | G(1-1/2)" |
| DL220DD160 | 3230 | 1020 | 445 | 1070 | 1120 | 2930 | 732.5 | 4 | 165 | 22 | 35 |
Remark:1,The refrigerating capacity test ata environmental temperature 32 ℃. 2,OEM is attept.
Application




FAQs
-
1. Where is the CDB series cooler primarily used?
-
2. What is the casing made of, and is it easy to maintain?
-
3. Are there options to control the noise level of the equipment?
-
4. What defrosting methods does this cooler support?
-
5. Which refrigerants are compatible with this unit?