China CDB Dual-Discharge Cooler - Lightweight Anti-Corrosive Design from Trusted Suppliers and Factory
Product Features
CDB series commercial dual discharge coolers is mainly used in small operating rooms.
1. Casing
Al-Mg alloy sheet with powder coating RAL9003, strong anti-corrosion performance and light weight. Outer drip tray adopts integral hinged structure, easy to clean and operate.
2. Heat Exchanger Coil
Copper tubing Φ12, Spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm & 6.4mm.
3. Fans
Axial fans, working temperature -40℃~60℃, fans individually connected to junction box. Fan specification Φ350, number from 1 to 4, fan motors are divided into 4-poles and 6-poles to meet different noise requirements.
4. Defrosting
Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting & water plate electric defrosting can also be used.
5. Refrigerants
It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.
Technical Data
| Model | KW | Cooling Area | Fan | Defrost electrical heater | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Air volume(cmh) | Diameter of fans(mm) | Quantity (set) | Power (w) | Voltage | Coil (kw) | Quantity | Coil(W) | Quantity | Total(W) | Voltage (V) | |||
| DL3.9/20 | 3.9 | 20 | 3400 | 300 | 2 | 164 | (V) | 1600 | 2 | 1600 | 2 | 3200 | 220 |
| DL5.8/30 | 5.8 | 30 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DL7.8/40 | 7.8 | 40 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DL10.7/55 | 10.7 | 55 | 6900 | 350 | 3 | 375 | 220 | 3300 | 2 | 3300 | 2 | 6600 | 220 |
| DL15.5/80 | 15.5 | 80 | 9200 | 350 | 4 | 500 | 380 | 2400 | 2 | 2400 | 2 | 4800 | 380 |
| DL20.3/105 | 20.3 | 105 | 12000 | 400 | 4 | 740 | 380 | 4600 | 2 | 4600 | 2 | 9200 | 380 |
| DL26.2/135 | 26.2 | 135 | 16000 | 450 | 4 | 920 | 380 | 5000 | 2 | 5000 | 2 | 10000 | 380 |
| DL31.0/160 | 31.0 | 160 | 16000 | 450 | 4 | 920 | 380 | 5200 | 2 | 5200 | 2 | 10400 | 380 |
| DL35.9/185 | 35.9 | 185 | 16000 | 450 | 4 | 920 | 380 | 6000 | 2 | 6000 | 2 | 12000 | 380 |
| DL42.6/220 | 42.6 | 220 | 19200 | 450 | 4 | 1000 | 380 | 6400 | 2 | 6400 | 2 | 12800 | 380 |
Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
| Model | KW | Cooling Area | Fan | Defrost electrical heater | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Air volume(cmh) | Diameter of fans(mm) | Quantity (set) | Power (w) | Voltage | Coil (kw) | Quantity | Coil(W) | Quantity | Total(W) | Voltage (V) | |||
| DD2.7/15 | 2.7 | 15 | 3400 | 300 | 2 | 164 | 220 | 1600 | 2 | 1600 | 2 | 3200 | 220 |
| DD3.9/22 | 3.9 | 22 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DD5.4/30 | 5.4 | 30 | 4600 | 350 | 2 | 250 | 220 | 2400 | 2 | 2400 | 2 | 4800 | 220 |
| DD7.2/40 | 7.2 | 40 | 6900 | 350 | 3 | 375 | 220 | 3300 | 2 | 3300 | 2 | 6600 | 220 |
| DD10.7/60 | 10.7 | 60 | 9200 | 350 | 4 | 500 | 380 | 2400 | 2 | 2400 | 2 | 4800 | 380 |
| DD14.3/80 | 14.3 | 80 | 12000 | 400 | 4 | 740 | 380 | 4600 | 2 | 4600 | 2 | 9200 | 380 |
| DD17.8/100 | 17.8 | 100 | 16000 | 450 | 4 | 920 | 380 | 5000 | 2 | 5000 | 2 | 10000 | 380 |
| DD21.4/120 | 21.4 | 120 | 16000 | 450 | 4 | 920 | 380 | 5200 | 2 | 5200 | 2 | 10400 | 380 |
| DD25.0/140 | 25.0 | 140 | 16000 | 450 | 4 | 920 | 380 | 6000 | 2 | 6000 | 2 | 12000 | 380 |
| DD28.6/160 | 28.6 | 160 | 19200 | 450 | 4 | 1000 | 380 | 6400 | 2 | 6400 | 2 | 12800 | 380 |
Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
Product Display
Installation Dimensions
| MODEL | A | B | C | D | W | E | E1 | N | F | Cycle pipe | Inlet tube connector | Outlet tube connector |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DL20 DD15 |
940 | 680 | 345 | 730 | 780 | 730 | 365 | 2 | 120 | 12 | 22 | G1" |
| DL30 DD22 |
1240 | 730 | 345 | 780 | 830 | 1030 | 515 | 2 | 120 | 12 | 22 | |
| DL40 DD30 |
1340 | 780 | 345 | 830 | 880 | 1130 | 565 | 2 | 120 | 16 | 28 | |
| DL55 DD40 |
1740 | 780 | 345 | 830 | 880 | 1530 | 510 | 3 | 120 | 16 | 28 | |
| DL80 DD60 |
2330 | 820 | 345 | 870 | 920 | 2030 | 507.5 | 4 | 165 | 16 | 28 | |
| DL105 DD80 |
2930 | 870 | 345 | 920 | 970 | 2630 | 657.5 | 4 | 165 | 19 | 32 | |
| DL135 DD100 |
2730 | 920 | 445 | 970 | 1020 | 2430 | 607.5 | 4 | 165 | 19 | 32 | |
| DL160 DD120 |
2830 | 1020 | 395 | 1070 | 1120 | 2530 | 632.5 | 4 | 165 | 19 | 32 | |
| DL185 DD140 |
2830 | 1020 | 445 | 1070 | 1120 | 2530 | 632.5 | 4 | 165 | 22 | 35 | G(1-1/2)" |
| DL220 DD160 |
3230 | 1020 | 445 | 1070 | 1120 | 2930 | 732.5 | 4 | 165 | 22 | 35 |
Remark: 1. The refrigerating capacity test at environmental temperature 32 ℃. 2. OEM is accepted.
Application
Frequently Asked Questions (FAQ)
What are the primary applications for CDB series commercial dual discharge coolers?
CDB series commercial dual discharge coolers are mainly designed and used in small operating rooms to provide efficient and balanced cooling.
What materials are used for the cooler casing?
The casing is made of high-quality Al-Mg alloy sheet finished with a RAL9003 powder coating, offering excellent anti-corrosion performance and a lightweight structure. The outer drip tray also features an integrated hinged structure for easy maintenance and cleaning.
What defrosting systems are compatible with these coolers?
Electric defrosting is the standard configuration, utilizing stainless steel heating pipes inside the coil and inner water plate with an independent junction box. Additionally, hot gas defrosting or a combination of coil hot gas and water plate electric defrosting can be customized.
Which refrigerants can be used with the CDB series?
These units are highly versatile and can meet the operating requirements for various refrigerants, including R404A, R507A, R448A, R449A, R134a, and R22.
How does the fan configuration address noise and temperature requirements?
The axial fans operate within a wide temperature range of -40℃ to 60℃. Depending on the model, 1 to 4 fans (Φ350 specification) are used. The fan motors are available in both 4-pole and 6-pole configurations to satisfy different noise level requirements.
Does the manufacturer support OEM customization?
Yes, OEM customization is accepted to satisfy specific project demands and technical standards.