High-Efficiency Air Cooler Series from China Suppliers and Factory - Automatic Defrosting, Low Noise, Energy Saving
Product Features
1. Panel and side plates are well constructed by using step structure, reducing the noise caused by fan and fan vibration. Water pan and side plate are easy to dismantle.
2. After treatment of phosphating and surface spray, the shell becomes corrosion resistance, smooth and achieves a longer life span.
3. Automatic molding process ensures dry and clean interior of the copper tube.
4. 2.6mpa air tightness test satisfies product air tightness requirements.
5. Expanded by liquid pressure machine, the aluminum fin and copper tube are combined tightly and achieves a stable effect of heat transfer.
6. Famous brand fan and heat tube achieves stable quality, low noise, less energy consumption and high efficiency.
7. Slot type rack design convenient for installation.
8. All wires and plugs are connected in an electrical box, convenient for installation and maintenance.
9. Electric defrosting selects high insulation performance stainless steel heating tube. Reasonable distribution achieves short time defrost, high efficiency and low consumption. Users can add module in the controller to realize the automatic defrosting control. Fast efficient defrosting and less energy cost.
Technical Data
| MODEL | Nominal capacity (W) |
Cooling Area (m²) |
Fin Space (mm) |
Pipe diameter (mm) |
Fan | Defrost electrical heater | |||||||
| Quantity (set) |
Diameter of fans (mm) |
Air volume (m³/h) |
wind pressure (mmH₂O) |
Power(w) | Voltage(V) | Coil (kw) |
Drain water plate (kW) |
Voltage (V) |
|||||
| DJ-1.2/8 | 1200 | 8 | 9 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DJ-2.1/15 | 2100 | 15 | 9 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 2.4 | 1.2 | 220 |
| DJ3.6/20 | 3600 | 20 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-4.6/30 | 4600 | 30 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-7.1/40 | 7100 | 40 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-8.9/55 | 8900 | 55 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-11.6/70 | 11600 | 70 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-14.3/85 | 14300 | 85 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-17.1/100 | 17100 | 100 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-19.6/115 | 19600 | 115 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-22/130 | 22000 | 130 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DJ-23/140 | 23000 | 140 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-25/150 | 25000 | 150 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-28/170 | 28000 | 170 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-30/190 | 30000 | 190 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-35/210 | 35000 | 210 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-41/250 | 41000 | 250 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DJ-50/300 | 50000 | 300 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DD-1.3/7 | 1300 | 7 | 6 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 1.0 | 0.5 | 220 |
| DD-2.2/12 | 2200 | 12 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DD2.8/15 | 2800 | 15 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 3x90 | 380 | 1.8 | 0.9 | 220 |
| DD-3.7/22 | 3700 | 22 | 6 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 2x90 | 380 | 2.4 | 1.2 | 220 |
| DD-5.6/30 | 5600 | 30 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-7.5/40 | 7500 | 40 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-11.2/60 | 11200 | 60 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-14.9/80 | 14900 | 80 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-18.7/100 | 18700 | 100 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-22.4/120 | 22400 | 120 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-26.4/140 | 26400 | 140 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DD-30.0/160 | 30000 | 160 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DD-35.0/180 | 35000 | 180 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DD-37.0/200 | 37000 | 200 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-40.0/220 | 40000 | 220 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-46.0/250 | 46000 | 250 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-50.0/275 | 50000 | 275 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-57.0/310 | 57000 | 310 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-67.0/360 | 67000 | 360 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DD-81.0/440 | 81000 | 440 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DL-2.0/10 | 2000 | 10 | 4.5 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 0.5 | 0.5 | 220 |
| DL-3.0/15 | 3000 | 15 | 4.5 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 0.9 | 0.9 | 220 |
| DL-5.0/25 | 5000 | 25 | 4.5 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 1.2 | 1.2 | 220 |
| DL-8.0/40 | 8000 | 40 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-11.2/55 | 11200 | 55 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-16.2/80 | 16200 | 80 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-21.0/105 | 21000 | 105 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-25.0/135 | 25000 | 135 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-32.6/160 | 32600 | 160 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-37.6/185 | 37600 | 185 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-42.7/220 | 42700 | 220 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 8.4 | 2.8 | 220 |
| DL-50.0/250 | 50000 | 250 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 9 | 3 | 220 |
| DL-55.0/280 | 55000 | 280 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-60.0/300 | 60000 | 300 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-66.0/330 | 66000 | 330 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-70.0/375 | 70000 | 375 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-82.0/410 | 82000 | 410 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-94.0/470 | 94000 | 470 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DL-116.0/580 | 11600 | 580 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
SDJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
SDD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
SDL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Product display
Installation Dimensions
Installation size of air cooler
| MODEL | L | D | D2 | F | E1 | N | H | Inlet | Cycle pipe | Inlet port | Water outlet |
| DL25/DD22/DJ15 | 1580 | 475 | 430 | 100 | 1380 | 1 | 604 | 12.7 | 19 | G1.5*1 | G2.5" |
| DL40/DD30/DJ20 | 1430 | 550 | 460 | 150 | 1130 | 1 | 704 | 16 | 25 | G1.5*1 | G2.5" |
| DL55/DD40/DJ30 | 1430 | 600 | 510 | 150 | 1130 | 1 | 704 | 16 | 25 | G1.5*1 | G2.5" |
| DL80/DD60/DJ40 | 1780 | 617.5 | 545 | 150 | 740 | 2 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL105/DD80/DJ55 | 1780 | 667.5 | 595 | 150 | 740 | 2 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL135/DD100/DJ70 | 2230 | 667.5 | 595 | 150 | 643 | 3 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL160/DD120/DJ85 | 2230 | 712.5 | 635 | 150 | 643 | 3 | 804 | 19 | 42 | G1.5*1 | G2.5" |
| DL185/DD140/DJ100 | 2830 | 667.5 | 595 | 150 | 643 | 3 | 804 | 22 | 50 | G1.5*1 | G2.5" |
| DL220/DD160/DJ115 | 2830 | 712.5 | 635 | 150 | 632.5 | 4 | 804 | 25 | 50 | G1.5*2 | G3" |
| DL250/DD180/DJ130 | 3180 | 712.5 | 635 | 150 | 720 | 4 | 804 | 25 | 50 | G1.5*2 | G4" |
| DL280/DD200/DJ140 | 2252 | 860 | 775 | 186 | 925 | 2 | 1032 | 25 | 50 | G1.5" | G3" |
| DL300/DD220/DJ150 | 2352 | 860 | 775 | 186 | 976 | 2 | 1032 | 25 | 50 | G1.5" | G3" |
| DL330/DD250/DJ170 | 2702 | 860 | 775 | 186 | 766 | 3 | 1032 | 25 | 50 | G1.5" | G3" |
| DL375/DD275/DJ190 | 2902 | 860 | 775 | 186 | 833 | 3 | 1032 | 25 | 50 | G1.5" | G4" |
| DL410/DD310/DJ210 | 3062 | 860 | 775 | 186 | 886 | 3 | 1032 | 25 | 50 | G1.5" | G4" |
| DL470/DD360/DJ250 | 3552 | 860 | 775 | 186 | 787 | 4 | 1082 | 25 | 50 | G1.5" | G4" |
| DL580/DD440/DJ300 | 3786 | 860 | 775 | 186 | 846 | 4 | 1182 | 28 | 50 | G1.5" | G4" |
Application
Fruit and vegetable preservation cold storage
Special medical cold storage
Flower preservation cold storage
Red wine storage cold storage
Aquatic product processing and storage cold storage
Special testing cold storage
Food processing cold storage
Frequently Asked Questions
How does the air cooler reduce fan and vibration noise?
The panel and side plates are well-constructed using a step structure, which effectively reduces the noise caused by the fan and fan vibration. Additionally, the water pan and side plate are designed to be easy to dismantle.
What treatment is applied to ensure the shell's durability?
The shell undergoes phosphating and surface spray treatments. This makes the surface smooth, highly corrosion-resistant, and ensures a longer product life span.
What air tightness standards do these air coolers meet?
Every unit undergoes a strict 2.6mpa air tightness test to satisfy the product's air tightness and safety requirements.
How is the defrosting system designed for energy efficiency?
The electric defrosting system uses high-insulation stainless steel heating tubes. Their reasonable distribution achieves a short defrosting time with high efficiency and low energy consumption. Users can also add a module to the controller to implement automatic defrosting control.
What are the capacity differences between the SDJ, SDD, and SDL series?
The series are rated under different temperature conditions: SDJ is based on an air inlet dry-bulb of -25℃ and evaporation of -31℃; SDD is based on an air inlet of -18℃ and evaporation of -25℃; and SDL is based on an air inlet of 0℃ and evaporation of -8℃.
What kind of applications are these air coolers suitable for?
These units are widely used in various cold storage environments, including fruit and vegetable preservation, special medical storage, flower preservation, red wine storage, aquatic product processing and storage, special testing, and food processing cold storage.