Hot Products

High-Efficiency Axial Flow Fan Cooler | China Suppliers & Factory for Versatile Refrigeration Solutions

,

Discover our high-efficiency unit cooler designed for optimal performance, featuring a robust RAL9003 powder-coated steel casing. This unit comes with easy-access hinged panels and integrated drip trays, making maintenance a breeze. The heat exchanger is crafted with premium copper tubes and corrugated aluminum fins for enhanced durability. Equipped with advanced axial fans and a specialized high air duct design, it guarantees low noise operation, exceptional ventilation, and an impressive long air throw. With standard electric defrosting and optional hot gas defrosting capabilities, this cooler is fully compatible with multiple refrigerants, including R404A, R134a, and R2As a leading supplier in China, our factory ensures that you receive top-quality cooling solutions suitable for diverse applications.

,

    Product Features

    1. Casing

    Adopt high-quality steel plate with powder coating RAL9003. Hinged structure is adopted for both side plates and external drip tray, which is convenient and quick to operate.

    2. Heat Exchanger Coil

    Copper tubing Φ12, spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm and 6.4mm and 9.0mm.

    3. Fans

    Axial fans with High wind circle, working temperature -40℃~60℃. High air duct design with integral stretching, good ventilation effect, further airthrow, lower noise. Fans individually connected to junction box. Fan blade φ300, φ350, φ400, φ500, standard 4-pole motor.

    4. Defrosting

    Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting can also be used.

    5. Refrigerant Compatibility

    It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.

    Technical Data

    MODEL Nominal capacity
    (W)
    Cooling Area
    (m²)
    Fin Space
    (mm)
    Pipe Diameter
    (mm)
    Axial flow fan Defrost electrical heater
    Quantity
    (set)
    Diameter of fans
    (mm)
    Air volume
    (m³/h)
    Wind pressure
    (mmH₂O)
    Power
    (w)
    Voltage
    (V)
    Coil
    (kw)
    Drain water plate
    (kW)
    Voltage
    (V)
    DJZ-8.9/55 8900 55 9 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DJZ-11.6/70 11600 70 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-14.3/85 14300 85 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-17.1/100 17100 100 9 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DJZ-19.6/115 19600 115 9 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DJZ-22/130 22000 130 9 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDJ-23/140 23000 140 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-25/150 25000 150 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-28/170 28000 170 9 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDJ-30/190 30000 190 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-35/210 35000 210 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-41/250 41000 250 9 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDJ-50/300 50000 300 9 16 4 600 4x12000 295 4x1500 380 30 3 380
    DDZ-14.9/80 14900 80 6 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DDZ-18.7/100 18700 100 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-22.4/120 22400 120 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-26.4/140 26400 140 6 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DDZ-30.0/160 30000 160 6 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DDZ-35.0/180 35000 180 6 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDD-37.0/200 37000 200 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-40.0/220 40000 220 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-46.0/250 46000 250 6 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDD-50.0/275 50000 275 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-57.0/310 57000 310 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-67.0/360 67000 360 6 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDD-81.0/440 81000 440 6 16 4 600 4x12000 295 4x1500 380 30 3 380
    DLZ-21.0/105 21000 105 4.5 16 2 500 2×6000 167 2×750 380 3 1.5 220
    DLZ-25.0/135 25000 135 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-32.6/160 32600 160 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-37.6/185 37600 185 4.5 16 3 500 3x6000 167 3x750 380 8.4 2.8 220
    DLZ-42.7/220 42700 220 4.5 16 4 500 4x6000 167 4x750 380 8.4 2.8 220
    DLZ-50.0/250 50000 250 4.5 16 4 500 4x6000 167 4x750 380 9 3 380
    ZDL-55.0/280 55000 280 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-60.0/300 60000 300 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-66.0/330 66000 330 4.5 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDL-70.0/375 70000 375 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-82.0/410 82000 410 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-94.0/470 94000 470 4.5 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDL-116.0/580 116000 580 4.5 16 4 600 4x12000 295 4x1500 380 30 3 380
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Product Display

    4c163bef4c2458182f19866c306bcb06
    10264dbd221f84529dcb91d6dd5a2e4d
    a121119f2a08d1fbad6ee3f37b4b6a13
    bcaea268756de3ddfe1102bd33be59f5
    c7a23144c53d49aed4179607f129d37f
    f64f4feb7ecffd03a5d51b4901912bbb

    Installation Dimensions

    MODEL L D D2 F E1 N H Inlet Cycle pipe Water outlet
    DDZ80/DLZ105/DJZ55 1780 880 490 152.5 737.5 2 720 19 38 G1"
    DDZ100/DLZ135/DJZ70 2230 880 490 152.5 641.5 3 720 22 50 G1"
    DDZ120/DLZ160/DJZ85 2230 945 555 152.5 641.5 3 720 22 50 G1"
    DDZ140/DLZ185/DJZ100 2920 880 490 197.5 841.5 3 720 22 50 G1"
    DDZ160/DLZ220/DJZ115 2920 945 555 197.5 631 4 720 22 50 G1.5"
    DDZ180/DLZ250/DJZ130 3250 945 555 187.5 718.5 4 720 25 50 G1.5"
    ZDD200/ZDL280/ZDJ140 2252 1140 775 186 925 2 885 25 50 G1.5"
    ZDD220/ZDL300/ZDJ150 2352 1140 775 186 976 2 885 25 50 G1.5"
    ZDD250/ZDL330/ZDJ170 2702 1140 775 186 766 3 885 25 50 G1.5"
    ZDD275/ZDL375/ZDJ190 2902 1140 775 186 833 3 885 25 50 G1.5"
    ZDD310/ZDL410/ZDJ210 3062 1140 775 186 886 3 885 25 50 G1.5"
    ZDD360/ZDL470/ZDJ250 3552 1140 775 186 787 4 935 25 50 G1.5"
    ZDD440/ZDL580/ZDJ300 3786 1140 775 186 846 4 1035 28 50 G1.5"
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Application

    a63547f8cc2bd384d2e14451bd8d375e
    ab71dd110b8bcfe9b78c789826cb4347

    Frequently Asked Questions (FAQ)

    Q1: What materials are used for the unit casing and drip tray?

    A1: The casing is made of high-quality steel plates with a powder coating finish in RAL9003. A hinged structure is incorporated for both the side plates and the external drip tray to ensure convenient operation and quick maintenance access.

    Q2: What are the technical specifications of the heat exchanger coil?

    A2: The heat exchanger coil utilizes Φ12 copper tubing with a spacing of 38.1x33. It features corrugated aluminium fins, with available fin spacing options of 4.2mm, 6.4mm, and 9.0mm to suit different working conditions.

    Q3: What types of defrosting methods are supported?

    A3: The standard configuration uses electric defrosting with stainless heating pipes installed in the middle of the coil and inner water plate, using an independent junction box. Hot gas defrosting or coil hot gas defrosting options are also available.

    Q4: What refrigerants are compatible with these cooling units?

    A4: The cooling units are designed to meet the operational requirements of R404A, R507A, R448A, R449A, R134a, R22, and other standard refrigerants.

    Q5: How are the axial flow fans configured?

    A5: The units use axial fans with a high wind circle, operating within a temperature range of -40℃ to 60℃. They feature an integral stretching high air duct design for improved ventilation, longer air throw, and lower noise levels, with each fan individually connected to a junction box.

    Q6: How are the cooling capacities for DJ, DD, and DL models calculated?

    A6: DJ capacity is based on -25℃ air inlet dry-bulb / -31℃ evaporation / 20℃ liquid temperature. DD capacity is based on -18℃ air inlet dry-bulb / -25℃ evaporation / 20℃ liquid temperature. DL capacity is based on 0℃ air inlet dry-bulb / -8℃ evaporation / 30℃ liquid temperature.