High-Efficiency Axial Flow Fan Unit Cooler from China Suppliers | Durable Factory Design and Versatile Refrigeration Solutions
Product Features
1. Casing
Adopt high-quality steel plate with powder coating RAL9003. Hinged structure is adopted for both side plates and external drip tray, which is convenient and quick to operate.
2. Heat Exchanger Coil
Copper tubing Φ12, spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm, 6.4mm, and 9.0mm.
3. Fans
Axial fans with High wind circle, working temperature -40℃~60℃. High air duct design with integral stretching, good ventilation effect, further airthrow, and lower noise. Fans individually connected to junction box. Fan blade φ300, φ350, φ400, φ500, standard 4-pole motor.
4. Defrosting
Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting can also be used.
5. Refrigerant Compatibility
It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.
Technical Data
| MODEL | Nominal capacity (W) |
Cooling Area (m²) |
Fin Space (mm) |
Pipe Diameter (mm) |
Axial flow fan | Defrost electrical heater | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Quantity (set) |
Diameter of fans (mm) |
Air volume (m³/h) |
Wind pressure (mmH₂O) |
Power (w) |
Voltage (V) |
Coil (kw) |
Drain water plate (kW) |
Voltage (V) |
|||||
| DJZ-8.9/55 | 8900 | 55 | 9 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 4.5 | 1.5 | 220 |
| DJZ-11.6/70 | 11600 | 70 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DJZ-14.3/85 | 14300 | 85 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DJZ-17.1/100 | 17100 | 100 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 11.2 | 2.8 | 220 |
| DJZ-19.6/115 | 19600 | 115 | 9 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 11.2 | 2.8 | 220 |
| DJZ-22/130 | 22000 | 130 | 9 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 12 | 3 | 380 |
| ZDJ-23/140 | 23000 | 140 | 9 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDJ-25/150 | 25000 | 150 | 9 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDJ-28/170 | 28000 | 170 | 9 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-30/190 | 30000 | 190 | 9 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-35/210 | 35000 | 210 | 9 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-41/250 | 41000 | 250 | 9 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDJ-50/300 | 50000 | 300 | 9 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
| DDZ-14.9/80 | 14900 | 80 | 6 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 4.5 | 1.5 | 220 |
| DDZ-18.7/100 | 18700 | 100 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DDZ-22.4/120 | 22400 | 120 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DDZ-26.4/140 | 26400 | 140 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 11.2 | 2.8 | 220 |
| DDZ-30.0/160 | 30000 | 160 | 6 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 11.2 | 2.8 | 220 |
| DDZ-35.0/180 | 35000 | 180 | 6 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 12 | 3 | 380 |
| ZDD-37.0/200 | 37000 | 200 | 6 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDD-40.0/220 | 40000 | 220 | 6 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDD-46.0/250 | 46000 | 250 | 6 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-50.0/275 | 50000 | 275 | 6 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-57.0/310 | 57000 | 310 | 6 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-67.0/360 | 67000 | 360 | 6 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDD-81.0/440 | 81000 | 440 | 6 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
| DLZ-21.0/105 | 21000 | 105 | 4.5 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 3 | 1.5 | 220 |
| DLZ-25.0/135 | 25000 | 135 | 4.5 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 6.3 | 2.1 | 220 |
| DLZ-32.6/160 | 32600 | 160 | 4.5 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 6.3 | 2.1 | 220 |
| DLZ-37.6/185 | 37600 | 185 | 4.5 | 16 | 3 | 500 | 3x6000 | 167 | 3x750 | 380 | 8.4 | 2.8 | 220 |
| DLZ-42.7/220 | 42700 | 220 | 4.5 | 16 | 4 | 500 | 4x6000 | 167 | 4x750 | 380 | 8.4 | 2.8 | 220 |
| DLZ-50.0/250 | 50000 | 250 | 4.5 | 16 | 4 | 500 | 4x6000 | 167 | 4x750 | 380 | 9 | 3 | 380 |
| ZDL-55.0/280 | 55000 | 280 | 4.5 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDL-60.0/300 | 60000 | 300 | 4.5 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDL-66.0/330 | 66000 | 330 | 4.5 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-70.0/375 | 70000 | 375 | 4.5 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-82.0/410 | 82000 | 410 | 4.5 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-94.0/470 | 94000 | 470 | 4.5 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDL-116.0/580 | 116000 | 580 | 4.5 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Product Display
Installation Dimensions
| MODEL | L | D | D2 | F | E1 | N | H | Inlet | Cycle pipe | Water outlet |
|---|---|---|---|---|---|---|---|---|---|---|
| DDZ80/DLZ105/DJZ55 | 1780 | 880 | 490 | 152.5 | 737.5 | 2 | 720 | 19 | 38 | G1" |
| DDZ100/DLZ135/DJZ70 | 2230 | 880 | 490 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ120/DLZ160/DJZ85 | 2230 | 945 | 555 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ140/DLZ185/DJZ100 | 2920 | 880 | 490 | 197.5 | 841.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ160/DLZ220/DJZ115 | 2920 | 945 | 555 | 197.5 | 631 | 4 | 720 | 22 | 50 | G1.5" |
| DDZ180/DLZ250/DJZ130 | 3250 | 945 | 555 | 187.5 | 718.5 | 4 | 720 | 25 | 50 | G1.5" |
| ZDD200/ZDL280/ZDJ140 | 2252 | 1140 | 775 | 186 | 925 | 2 | 885 | 25 | 50 | G1.5" |
| ZDD220/ZDL300/ZDJ150 | 2352 | 1140 | 775 | 186 | 976 | 2 | 885 | 25 | 50 | G1.5" |
| ZDD250/ZDL330/ZDJ170 | 2702 | 1140 | 775 | 186 | 766 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD275/ZDL375/ZDJ190 | 2902 | 1140 | 775 | 186 | 833 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD310/ZDL410/ZDJ210 | 3062 | 1140 | 775 | 186 | 886 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD360/ZDL470/ZDJ250 | 3552 | 1140 | 775 | 186 | 787 | 4 | 935 | 25 | 50 | G1.5" |
| ZDD440/ZDL580/ZDJ300 | 3786 | 1140 | 775 | 186 | 846 | 4 | 1035 | 28 | 50 | G1.5" |
DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Application
Frequently Asked Questions
What types of refrigerants are compatible with these cooling units?
These units are highly versatile and designed to meet the requirements of multiple common refrigerants, including R404A, R507A, R448A, R449A, R134a, and R22.
What defrosting configurations are available?
Electric defrosting is the standard configuration, featuring stainless steel heating pipes installed in the middle of the coil and the inner water plate, with an independent junction box. Hot gas defrosting or coil hot gas defrosting can also be configured upon request.
What are the specifications of the casing?
The casing uses high-quality steel plates finished with a protective RAL9003 powder coating. For easy maintenance, both the side plates and the external drip tray feature a hinged structure.
What are the differences between DJ, DD, and DL cooling capacities?
Each capacity rating is calculated based on specific temperature parameters:
• DJ Capacity: Air inlet dry-bulb -25℃, evaporation -31℃, liquid refrigerant 20℃.
• DD Capacity: Air inlet dry-bulb -18℃, evaporation -25℃, liquid refrigerant 20℃.
• DL Capacity: Air inlet dry-bulb 0℃, evaporation -8℃, liquid refrigerant 30℃.
• DJ Capacity: Air inlet dry-bulb -25℃, evaporation -31℃, liquid refrigerant 20℃.
• DD Capacity: Air inlet dry-bulb -18℃, evaporation -25℃, liquid refrigerant 20℃.
• DL Capacity: Air inlet dry-bulb 0℃, evaporation -8℃, liquid refrigerant 30℃.
What are the working conditions and features of the fan motors?
The units are equipped with axial fans with an integral stretching design that improves ventilation and airthrow while reducing noise. They operate reliably within a temperature range of -40℃ to 60℃ and are individually connected to a dedicated junction box. Standard 4-pole motors are available with fan blade diameters of φ300, φ350, φ400, and φ500.