Introducing the CDB dual-discharge cooler, an ideal solution for small operating rooms. Manufactured in China, this cooler boasts a lightweight and anti-corrosive Al-Mg alloy casing, complemented by an easy-to-clean hinged drip tray. Our factory utilizes high-efficiency copper tubes and aluminum fins to enhance cooling performance, while customizable low-noise axial fans ensure a quiet environment. This unit also offers versatile defrosting options, including electric and hot gas, catering to your specific needs. With broad compatibility, it supports various refrigerants such as R404A, R134a, and R22, making it a reliable choice for all your cooling requirements. Choose the CDB dual-discharge cooler from trusted suppliers for efficient and effective cooling solutions

    Product Features

    CDB series commercial dual discharge coolers is mainly used in small operating rooms.
    1. Casing

    Al-Mg alloy sheet with powder coating RAL9003, strong anti-corrosion performance and light weight. Outer drip tray adopts integral hinged structure, easy to clean and operate.

    2. Heat exchanger Coil

    Copper tubing Φ12, Spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm & 6.4mm.

    3. Fans

    Axial fans, working temperature -40℃~60℃, fans individually connected to junction box. Fan specification Φ350, number from 1 to 4, fan motors are divided into 4-poles and 6-poles to meet different noise requirements.

    4. Defrosting

    Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting & water plate electric defrosting can also be used.

    5. Refrigerant Compatibility

    It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.

    Technical Data

    Model KW Cooling Area Fan Defrost electrical heater
    Air volume(cmh) Diameter of fans(mm) Quantity
    (set)
    Power
    (w)
    Voltage Coil
    (kw)
    Quantity Coil(W) Quantity Total(W) Voltage
    (V)
    DL3.9/20 3.9 20 3400 300 2 164 (V) 1600 2 1600 2 3200 220
    DL5.8/30 5.8 30 4600 350 2 250 220 2400 2 2400 2 4800 220
    DL7.8/40 7.8 40 4600 350 2 250 220 2400 2 2400 2 4800 220
    DL10.7/55 10.7 55 6900 350 3 375 220 3300 2 3300 2 6600 220
    DL15.5/80 15.5 80 9200 350 4 500 380 2400 2 2400 2 4800 380
    DL20.3/105 20.3 105 12000 400 4 740 380 4600 2 4600 2 9200 380
    DL26.2/135 26.2 135 16000 450 4 920 380 5000 2 5000 2 10000 380
    DL31.0/160 31.0 160 16000 450 4 920 380 5200 2 5200 2 10400 380
    DL35.9/185 35.9 185 16000 450 4 920 380 6000 2 6000 2 12000 380
    DL42.6/220 42.6 220 19200 450 4 1000 380 6400 2 6400 2 12800 380
    Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
    Model KW Cooling Area Fan Defrost electrical heater
    Air volume(cmh) Diameter of fans(mm) Quantity
    (set)
    Power
    (w)
    Voltage Coil
    (kw)
    Quantity Coil(W) Quantity Total(W) Voltage
    (V)
    DD2.7/15 2.7 15 3400 300 2 164 220 1600 2 1600 2 3200 220
    DD3.9/22 3.9 22 4600 350 2 250 220 2400 2 2400 2 4800 220
    DD5.4/30 5.4 30 4600 350 2 250 220 2400 2 2400 2 4800 220
    DD7.2/40 7.2 40 6900 350 3 375 220 3300 2 3300 2 6600 220
    DD10.7/60 10.7 60 9200 350 4 500 380 2400 2 2400 2 4800 380
    DD14.3/80 14.3 80 12000 400 4 740 380 4600 2 4600 2 9200 380
    DD17.8/100 17.8 100 16000 450 4 920 380 5000 2 5000 2 10000 380
    DD21.4/120 21.4 120 16000 450 4 920 380 5200 2 5200 2 10400 380
    DD25.0/140 25.0 140 16000 450 4 920 380 6000 2 6000 2 12000 380
    DD28.6/160 28.6 160 19200 450 4 1000 380 6400 2 6400 2 12800 380
    Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.

    Product Display

    Installation Dimensions

    MODEL A B C D W E E1 N F Cycle pipe Inlet tube connector Outlet tube connector
    DL20
    DD15
    940 680 345 730 780 730 365 2 120 12 22 G1"
    DL30
    DD22
    1240 730 345 780 830 1030 515 2 120 12 22
    DL40
    DD30
    1340 780 345 830 880 1130 565 2 120 16 28
    DL55
    DD40
    1740 780 345 830 880 1530 510 3 120 16 28
    DL80
    DD60
    2330 820 345 870 920 2030 507.5 4 165 16 28
    DL105DD80 2930 870 345 920 970 2630 657.5 4 165 19 32
    DL135DD100 2730 920 445 970 1020 2430 607.5 4 165 19 32
    DL160DD120 2830 1020 395 1070 1120 2530 632.5 4 165 19 32
    DL185DD140 2830 1020 445 1070 1120 2530 632.5 4 165 22 35 G(1-1/2)"
    DL220DD160 3230 1020 445 1070 1120 2930 732.5 4 165 22 35
    Remark: 1, The refrigerating capacity test at environmental temperature 32 ℃. 2, OEM is accepted.

    Application

    Frequently Asked Questions (FAQ)

    Q: What are the primary applications for CDB series dual discharge coolers?

    A: CDB series commercial dual discharge coolers are primarily designed and optimized for use in small operating rooms and similar cold storage spaces where balanced, dual-direction airflow is required.

    Q: What casing material is used to ensure durability?

    A: The casing is constructed from an Al-Mg alloy sheet coated with RAL9003 powder. This combination provides excellent anti-corrosion properties and a lightweight design. It also features an integrated hinged outer drip tray for easy access and cleaning.

    Q: Which refrigerants are compatible with these coolers?

    A: The CDB series is highly versatile and fully compatible with R404A, R507A, R448A, R449A, R134a, R22, and other standard refrigerants.

    Q: What defrosting options do you offer?

    A: Electric defrosting is our standard configuration, featuring stainless steel heating pipes in the coil and inner water plate. However, we also support hot gas defrosting or a combination of coil hot gas defrosting with water plate electric defrosting.

    Q: Can the fan motors be customized for different noise levels?

    A: Yes, our axial fans (ranging from 1 to 4 sets, Φ350 specification) are available with either 4-pole or 6-pole motors to accommodate different airflow and noise requirements.

    Q: Do you accept OEM orders for the CDB series?

    A: Yes, OEM services are fully accepted. We can customize the dimensions and technical specifications to meet your specific application requirements.