Introducing our high-efficiency unit cooler, designed for optimal performance and durability. This product features a robust RAL9003 powder-coated steel casing, complete with easy-access hinged panels and drip trays for hassle-free maintenance. The heat exchanger is crafted with premium copper tubes and corrugated aluminum fins, ensuring efficient heat exchange. Equipped with advanced axial fans that incorporate a specialized high air duct design, this unit guarantees low noise levels, excellent ventilation, and extended air throw. It offers both standard electric and optional hot gas defrosting, making it fully compatible with various refrigerants such as R404A, R134a, and R2As a leading China supplier, our factory provides versatile cooling solutions suitable for a wide range of applications.

,

    Product Features

    1. Casing: Adopt high-quality steel plate with powder coating RAL9003. Hinged structure is adopted for both side plates and external drip tray, which is convenient and quick to operate;
    2. Heat Exchanger Coil: Copper tubing Φ12, spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm and 6.4mm and 9.0mm;
    3. Fans: Axial fans with High wind circle, working temperature -40℃~60℃. High air duct design with. Integral stretching, good ventilation effect, further airthrow, lower noise. Fans individually connected to junction box. Fan blade φ300, φ350, φ400, φ500, standard 4-pole motor;
    4. Defrosting: Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting can also be used.
    5. Refrigerant Compatibility: It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.

    Technical Data

    MODEL Nominal capacity
    (W)
    Cooling Area
    (m²)
    Fin Space
    (mm)
    Pipe Diameter
    (mm)
    Axial flow fan Defrost electrical heater
    Quantity
    (set)
    Diameter of fans
    (mm)
    Air volume
    (m³/h)
    Wind pressure
    (mmH₂O)
    Power
    (w)
    Voltage
    (V)
    Coil
    (kw)
    Drain water plate
    (kW)
    Voltage
    (V)
    DJZ-8.9/55 8900 55 9 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DJZ-11.6/70 11600 70 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-14.3/85 14300 85 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-17.1/100 17100 100 9 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DJZ-19.6/115 19600 115 9 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DJZ-22/130 22000 130 9 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDJ-23/140 23000 140 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-25/150 25000 150 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-28/170 28000 170 9 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDJ-30/190 30000 190 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-35/210 35000 210 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-41/250 41000 250 9 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDJ-50/300 50000 300 9 16 4 600 4x12000 295 4x1500 380 30 3 380
    DDZ-14.9/80 14900 80 6 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DDZ-18.7/100 18700 100 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-22.4/120 22400 120 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-26.4/140 26400 140 6 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DDZ-30.0/160 30000 160 6 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DDZ-35.0/180 35000 180 6 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDD-37.0/200 37000 200 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-40.0/220 40000 220 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-46.0/250 46000 250 6 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDD-50.0/275 50000 275 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-57.0/310 57000 310 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-67.0/360 67000 360 6 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDD-81.0/440 81000 440 6 16 4 600 4x12000 295 4x1500 380 30 3 380
    DLZ-21.0/105 21000 105 4.5 16 2 500 2×6000 167 2×750 380 3 1.5 220
    DLZ-25.0/135 25000 135 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-32.6/160 32600 160 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-37.6/185 37600 185 4.5 16 3 500 3x6000 167 3x750 380 8.4 2.8 220
    DLZ-42.7/220 42700 220 4.5 16 4 500 4x6000 167 4x750 380 8.4 2.8 220
    DLZ-50.0/250 50000 250 4.5 16 4 500 4x6000 167 4x750 380 9 3 380
    ZDL-55.0/280 55000 280 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-60.0/300 60000 300 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-66.0/330 66000 330 4.5 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDL-70.0/375 70000 375 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-82.0/410 82000 410 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-94.0/470 94000 470 4.5 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDL-116.0/580 116000 580 4.5 16 4 600 4x12000 295 4x1500 380 30 3 380
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Product Display

    4c163bef4c2458182f19866c306bcb06
    10264dbd221f84529dcb91d6dd5a2e4d
    a121119f2a08d1fbad6ee3f37b4b6a13
    bcaea268756de3ddfe1102bd33be59f5
    c7a23144c53d49aed4179607f129d37f
    f64f4feb7ecffd03a5d51b4901912bbb

    Installation Dimensions

    MODEL L D D2 F E1 N H Inlet Cycle pipe Water outlet
    DDZ80/DLZ105/DJZ55 1780 880 490 152.5 737.5 2 720 19 38 G1"
    DDZ100/DLZ135/DJZ70 2230 880 490 152.5 641.5 3 720 22 50 G1"
    DDZ120/DLZ160/DJZ85 2230 945 555 152.5 641.5 3 720 22 50 G1"
    DDZ140/DLZ185/DJZ100 2920 880 490 197.5 841.5 3 720 22 50 G1"
    DDZ160/DLZ220/DJZ115 2920 945 555 197.5 631 4 720 22 50 G1.5"
    DDZ180/DLZ250/DJZ130 3250 945 555 187.5 718.5 4 720 25 50 G1.5"
    ZDD200/ZDL280/ZDJ140 2252 1140 775 186 925 2 885 25 50 G1.5"
    ZDD220/ZDL300/ZDJ150 2352 1140 775 186 976 2 885 25 50 G1.5"
    ZDD250/ZDL330/ZDJ170 2702 1140 775 186 766 3 885 25 50 G1.5"
    ZDD275/ZDL375/ZDJ190 2902 1140 775 186 833 3 885 25 50 G1.5"
    ZDD310/ZDL410/ZDJ210 3062 1140 775 186 886 3 885 25 50 G1.5"
    ZDD360/ZDL470/ZDJ250 3552 1140 775 186 787 4 935 25 50 G1.5"
    ZDD440/ZDL580/ZDJ300 3786 1140 775 186 846 4 1035 28 50 G1.5"
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Application

    a63547f8cc2bd384d2e14451bd8d375e
    ab71dd110b8bcfe9b78c789826cb4347

    Frequently Asked Questions (FAQ)

    What type of refrigerants are supported by these cooling coils?
    These units are highly versatile and compatible with a wide range of refrigerants, including R404A, R507A, R448A, R449A, R134a, R22, and other common refrigeration agents.
    What are the casing features and how convenient is maintenance?
    The casing is constructed from high-quality steel plates finished with a clean RAL9003 powder coating. For quick and easy maintenance, both the side plates and the external drip tray feature a hinged structure design.
    What defrosting options are available for these units?
    Electric defrosting is the standard configuration, utilizing stainless heating pipes installed within the coil and inner water plate. However, hot gas defrosting or coil hot gas defrosting can also be accommodated based on system requirements.
    What are the operating limits and specifications of the axial fans?
    The high wind circle axial fans are designed to operate reliably within a wide temperature range of -40℃ to 60℃. They feature standard 4-pole motors with fan blades available in φ300, φ350, φ400, and φ500 dimensions.
    How are the cooling capacities for the DJ, DD, and DL series determined?
    Cooling capacities are rated based on specific conditions: DJ series at -25℃ inlet / -31℃ evaporation; DD series at -18℃ inlet / -25℃ evaporation; and DL series at 0℃ inlet / -8℃ evaporation.