High-Efficiency Axial Flow Fan Cooler - China Suppliers & Factory | Versatile Refrigerant Compatibility
Product Features
1. Casing: Adopt high-quality steel plate with powder coating RAL9003. Hinged structure is adopted for both side plates and external drip tray, which is convenient and quick to operate;
2. Heat Exchanger Coil: Copper tubing Φ12, spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm and 6.4mm and 9.0mm;
3. Fans: Axial fans with High wind circle, working temperature -40℃~60℃. High air duct design with. Integral stretching, good ventilation effect, further airthrow, lower noise. Fans individually connected to junction box. Fan blade φ300, φ350, φ400, φ500, standard 4-pole motor;
4. Defrosting: Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting can also be used.
5. Refrigerant Compatibility: It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.
Technical Data
| MODEL | Nominal capacity (W) |
Cooling Area (m²) |
Fin Space (mm) |
Pipe Diameter (mm) |
Axial flow fan | Defrost electrical heater | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Quantity (set) |
Diameter of fans (mm) |
Air volume (m³/h) |
Wind pressure (mmH₂O) |
Power (w) |
Voltage (V) |
Coil (kw) |
Drain water plate (kW) |
Voltage (V) |
|||||
| DJZ-8.9/55 | 8900 | 55 | 9 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 4.5 | 1.5 | 220 |
| DJZ-11.6/70 | 11600 | 70 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DJZ-14.3/85 | 14300 | 85 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DJZ-17.1/100 | 17100 | 100 | 9 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 11.2 | 2.8 | 220 |
| DJZ-19.6/115 | 19600 | 115 | 9 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 11.2 | 2.8 | 220 |
| DJZ-22/130 | 22000 | 130 | 9 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 12 | 3 | 380 |
| ZDJ-23/140 | 23000 | 140 | 9 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDJ-25/150 | 25000 | 150 | 9 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDJ-28/170 | 28000 | 170 | 9 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-30/190 | 30000 | 190 | 9 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-35/210 | 35000 | 210 | 9 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDJ-41/250 | 41000 | 250 | 9 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDJ-50/300 | 50000 | 300 | 9 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
| DDZ-14.9/80 | 14900 | 80 | 6 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 4.5 | 1.5 | 220 |
| DDZ-18.7/100 | 18700 | 100 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DDZ-22.4/120 | 22400 | 120 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 8.4 | 2.1 | 220 |
| DDZ-26.4/140 | 26400 | 140 | 6 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 11.2 | 2.8 | 220 |
| DDZ-30.0/160 | 30000 | 160 | 6 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 11.2 | 2.8 | 220 |
| DDZ-35.0/180 | 35000 | 180 | 6 | 16 | 4 | 500 | 4×6000 | 167 | 4×750 | 380 | 12 | 3 | 380 |
| ZDD-37.0/200 | 37000 | 200 | 6 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDD-40.0/220 | 40000 | 220 | 6 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDD-46.0/250 | 46000 | 250 | 6 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-50.0/275 | 50000 | 275 | 6 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-57.0/310 | 57000 | 310 | 6 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDD-67.0/360 | 67000 | 360 | 6 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDD-81.0/440 | 81000 | 440 | 6 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
| DLZ-21.0/105 | 21000 | 105 | 4.5 | 16 | 2 | 500 | 2×6000 | 167 | 2×750 | 380 | 3 | 1.5 | 220 |
| DLZ-25.0/135 | 25000 | 135 | 4.5 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 6.3 | 2.1 | 220 |
| DLZ-32.6/160 | 32600 | 160 | 4.5 | 16 | 3 | 500 | 3×6000 | 167 | 3×750 | 380 | 6.3 | 2.1 | 220 |
| DLZ-37.6/185 | 37600 | 185 | 4.5 | 16 | 3 | 500 | 3x6000 | 167 | 3x750 | 380 | 8.4 | 2.8 | 220 |
| DLZ-42.7/220 | 42700 | 220 | 4.5 | 16 | 4 | 500 | 4x6000 | 167 | 4x750 | 380 | 8.4 | 2.8 | 220 |
| DLZ-50.0/250 | 50000 | 250 | 4.5 | 16 | 4 | 500 | 4x6000 | 167 | 4x750 | 380 | 9 | 3 | 380 |
| ZDL-55.0/280 | 55000 | 280 | 4.5 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDL-60.0/300 | 60000 | 300 | 4.5 | 16 | 2 | 600 | 2x12000 | 167 | 2x1500 | 380 | 24 | 3 | 380 |
| ZDL-66.0/330 | 66000 | 330 | 4.5 | 16 | 3 | 600 | 3x12000 | 167 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-70.0/375 | 70000 | 375 | 4.5 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-82.0/410 | 82000 | 410 | 4.5 | 16 | 3 | 600 | 3x12000 | 295 | 3x1500 | 380 | 24 | 3 | 380 |
| ZDL-94.0/470 | 94000 | 470 | 4.5 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 27 | 3 | 380 |
| ZDL-116.0/580 | 116000 | 580 | 4.5 | 16 | 4 | 600 | 4x12000 | 295 | 4x1500 | 380 | 30 | 3 | 380 |
DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Product Display
Installation Dimensions
| MODEL | L | D | D2 | F | E1 | N | H | Inlet | Cycle pipe | Water outlet |
|---|---|---|---|---|---|---|---|---|---|---|
| DDZ80/DLZ105/DJZ55 | 1780 | 880 | 490 | 152.5 | 737.5 | 2 | 720 | 19 | 38 | G1" |
| DDZ100/DLZ135/DJZ70 | 2230 | 880 | 490 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ120/DLZ160/DJZ85 | 2230 | 945 | 555 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ140/DLZ185/DJZ100 | 2920 | 880 | 490 | 197.5 | 841.5 | 3 | 720 | 22 | 50 | G1" |
| DDZ160/DLZ220/DJZ115 | 2920 | 945 | 555 | 197.5 | 631 | 4 | 720 | 22 | 50 | G1.5" |
| DDZ180/DLZ250/DJZ130 | 3250 | 945 | 555 | 187.5 | 718.5 | 4 | 720 | 25 | 50 | G1.5" |
| ZDD200/ZDL280/ZDJ140 | 2252 | 1140 | 775 | 186 | 925 | 2 | 885 | 25 | 50 | G1.5" |
| ZDD220/ZDL300/ZDJ150 | 2352 | 1140 | 775 | 186 | 976 | 2 | 885 | 25 | 50 | G1.5" |
| ZDD250/ZDL330/ZDJ170 | 2702 | 1140 | 775 | 186 | 766 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD275/ZDL375/ZDJ190 | 2902 | 1140 | 775 | 186 | 833 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD310/ZDL410/ZDJ210 | 3062 | 1140 | 775 | 186 | 886 | 3 | 885 | 25 | 50 | G1.5" |
| ZDD360/ZDL470/ZDJ250 | 3552 | 1140 | 775 | 186 | 787 | 4 | 935 | 25 | 50 | G1.5" |
| ZDD440/ZDL580/ZDJ300 | 3786 | 1140 | 775 | 186 | 846 | 4 | 1035 | 28 | 50 | G1.5" |
DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Application
Frequently Asked Questions (FAQ)
What type of refrigerants are supported by these cooling coils?
These units are highly versatile and compatible with a wide range of refrigerants, including R404A, R507A, R448A, R449A, R134a, R22, and other common refrigeration agents.
What are the casing features and how convenient is maintenance?
The casing is constructed from high-quality steel plates finished with a clean RAL9003 powder coating. For quick and easy maintenance, both the side plates and the external drip tray feature a hinged structure design.
What defrosting options are available for these units?
Electric defrosting is the standard configuration, utilizing stainless heating pipes installed within the coil and inner water plate. However, hot gas defrosting or coil hot gas defrosting can also be accommodated based on system requirements.
What are the operating limits and specifications of the axial fans?
The high wind circle axial fans are designed to operate reliably within a wide temperature range of -40℃ to 60℃. They feature standard 4-pole motors with fan blades available in φ300, φ350, φ400, and φ500 dimensions.
How are the cooling capacities for the DJ, DD, and DL series determined?
Cooling capacities are rated based on specific conditions: DJ series at -25℃ inlet / -31℃ evaporation; DD series at -18℃ inlet / -25℃ evaporation; and DL series at 0℃ inlet / -8℃ evaporation.