This high-efficiency unit cooler, designed for optimal performance, boasts a robust RAL9003 powder-coated steel casing and is equipped with convenient hinged panels and drip trays for easy maintenance. The heat exchanger is crafted with premium copper tubes and corrugated aluminum fins, ensuring excellent heat transfer. Featuring advanced axial fans designed for exceptional airflow, this cooler operates quietly while delivering superior ventilation and an impressive air throw. It supports standard electric and optional hot gas defrosting, making it a versatile choice for various cooling applications. Fully compatible with multiple refrigerants, including R404A, R134a, and R22, this unit is an ideal solution for businesses in China seeking reliable cooling solutions. As a leading factory and suppliers, we provide high-quality products that meet demanding industrial standards

    Product Features

    1. Casing

    Adopt high-quality steel plate with powder coating RAL9003. Hinged structure is adopted for both side plates and external drip tray, which is convenient and quick to operate.

    2. Heat Exchanger Coil

    Copper tubing Φ12, spacing 38.1x33; Corrugated aluminium fins, fin spacing 4.2mm and 6.4mm and 9.0mm.

    3. Fans

    Axial fans with High wind circle, working temperature -40℃~60℃. High air duct design with integral stretching, good ventilation effect, further airthrow, lower noise. Fans individually connected to junction box. Fan blade φ300, φ350, φ400, φ500, standard 4-pole motor.

    4. Defrosting

    Standard use of electric defrosting, stainless heating pipes installed in the middle of coil and inner water plate. Independent electric heating tube junction box. Hot gas defrosting or coil hot gas defrosting can also be used.

    5. Refrigerants Compatibility

    It can meet the requirements of R404A, R507A, R448A, R449A, R134a, R22 and other refrigerants.

    Technical Data

    MODEL Nominal capacity
    (W)
    Cooling Area
    (m²)
    Fin Space
    (mm)
    Pipe Diameter
    (mm)
    Axial flow fan Defrost electrical heater
    Quantity
    (set)
    Diameter of fans
    (mm)
    Air volume
    (m³/h)
    Wind pressure
    (mmH₂O)
    Power
    (w)
    Voltage
    (V)
    Coil
    (kw)
    Drain water plate
    (kW)
    Voltage
    (V)
    DJZ-8.9/55 8900 55 9 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DJZ-11.6/70 11600 70 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-14.3/85 14300 85 9 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DJZ-17.1/100 17100 100 9 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DJZ-19.6/115 19600 115 9 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DJZ-22/130 22000 130 9 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDJ-23/140 23000 140 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-25/150 25000 150 9 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDJ-28/170 28000 170 9 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDJ-30/190 30000 190 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-35/210 35000 210 9 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDJ-41/250 41000 250 9 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDJ-50/300 50000 300 9 16 4 600 4x12000 295 4x1500 380 30 3 380
    DDZ-14.9/80 14900 80 6 16 2 500 2×6000 167 2×750 380 4.5 1.5 220
    DDZ-18.7/100 18700 100 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-22.4/120 22400 120 6 16 3 500 3×6000 167 3×750 380 8.4 2.1 220
    DDZ-26.4/140 26400 140 6 16 3 500 3×6000 167 3×750 380 11.2 2.8 220
    DDZ-30.0/160 30000 160 6 16 4 500 4×6000 167 4×750 380 11.2 2.8 220
    DDZ-35.0/180 35000 180 6 16 4 500 4×6000 167 4×750 380 12 3 380
    ZDD-37.0/200 37000 200 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-40.0/220 40000 220 6 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDD-46.0/250 46000 250 6 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDD-50.0/275 50000 275 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-57.0/310 57000 310 6 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDD-67.0/360 67000 360 6 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDD-81.0/440 81000 440 6 16 4 600 4x12000 295 4x1500 380 30 3 380
    DLZ-21.0/105 21000 105 4.5 16 2 500 2×6000 167 2×750 380 3 1.5 220
    DLZ-25.0/135 25000 135 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-32.6/160 32600 160 4.5 16 3 500 3×6000 167 3×750 380 6.3 2.1 220
    DLZ-37.6/185 37600 185 4.5 16 3 500 3x6000 167 3x750 380 8.4 2.8 220
    DLZ-42.7/220 42700 220 4.5 16 4 500 4x6000 167 4x750 380 8.4 2.8 220
    DLZ-50.0/250 50000 250 4.5 16 4 500 4x6000 167 4x750 380 9 3 380
    ZDL-55.0/280 55000 280 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-60.0/300 60000 300 4.5 16 2 600 2x12000 167 2x1500 380 24 3 380
    ZDL-66.0/330 66000 330 4.5 16 3 600 3x12000 167 3x1500 380 24 3 380
    ZDL-70.0/375 70000 375 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-82.0/410 82000 410 4.5 16 3 600 3x12000 295 3x1500 380 24 3 380
    ZDL-94.0/470 94000 470 4.5 16 4 600 4x12000 295 4x1500 380 27 3 380
    ZDL-116.0/580 116000 580 4.5 16 4 600 4x12000 295 4x1500 380 30 3 380
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Product Display

    Product display 1
    Product display 2
    Product display 3
    Product display 4
    Product display 5
    Product display 6

    Installation Dimensions

    MODEL L D D2 F E1 N H Inlet Cycle pipe Water outlet
    DDZ80/DLZ105/DJZ55 1780 880 490 152.5 737.5 2 720 19 38 G1"
    DDZ100/DLZ135/DJZ70 2230 880 490 152.5 641.5 3 720 22 50 G1"
    DDZ120/DLZ160/DJZ85 2230 945 555 152.5 641.5 3 720 22 50 G1"
    DDZ140/DLZ185/DJZ100 2920 880 490 197.5 841.5 3 720 22 50 G1"
    DDZ160/DLZ220/DJZ115 2920 945 555 197.5 631 4 720 22 50 G1.5"
    DDZ180/DLZ250/DJZ130 3250 945 555 187.5 718.5 4 720 25 50 G1.5"
    ZDD200/ZDL280/ZDJ140 2252 1140 775 186 925 2 885 25 50 G1.5"
    ZDD220/ZDL300/ZDJ150 2352 1140 775 186 976 2 885 25 50 G1.5"
    ZDD250/ZDL330/ZDJ170 2702 1140 775 186 766 3 885 25 50 G1.5"
    ZDD275/ZDL375/ZDJ190 2902 1140 775 186 833 3 885 25 50 G1.5"
    ZDD310/ZDL410/ZDJ210 3062 1140 775 186 886 3 885 25 50 G1.5"
    ZDD360/ZDL470/ZDJ250 3552 1140 775 186 787 4 935 25 50 G1.5"
    ZDD440/ZDL580/ZDJ300 3786 1140 775 186 846 4 1035 28 50 G1.5"
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Application

    Application example 1
    Application example 2

    Frequently Asked Questions

    Q1: What materials are used for the casing of these cooling units?

    A: The casing is made of high-quality steel plate with a powder coating finish in RAL9003. It also features a hinged structure on both side plates and the external drip tray for convenient operation and maintenance.

    Q2: Which refrigerants are compatible with these heat exchanger coils?

    A: The units are highly versatile and can meet the requirements for various refrigerants, including R404A, R507A, R448A, R449A, R134a, and R22.

    Q3: What are the specifications of the fans used in these units?

    A: The units utilize axial fans with high wind circles, operating efficiently in temperatures ranging from -40℃ to 60℃. They feature standard 4-pole motors (fan blade diameters of φ300, φ350, φ400, or φ500) and are individually connected to the junction box.

    Q4: What defrosting methods are supported?

    A: Standard models use electric defrosting with stainless heating pipes installed in the middle of the coil and inner water plate. However, hot gas defrosting or coil hot gas defrosting can also be configured.

    Q5: How are the cooling capacities for DJ, DD, and DL models calculated?

    A: DJ capacity is based on -25℃ inlet air / -31℃ evaporation; DD capacity is based on -18℃ inlet air / -25℃ evaporation; DL capacity is based on 0℃ inlet air / -8℃ evaporation.