High Efficiency Evaporative Air Cooler Series - China Factory Direct HVAC Solutions from Top Suppliers
Product Features
Low Noise & Vibration: The panel and side plates adopt a stepped structural design, which effectively reduces fan operating noise and vibration. The water pan and side plates feature a detachable structure for easy disassembly and cleaning.
Corrosion Resistance: The equipment shell undergoes professional phosphating treatment and surface spraying processes, delivering excellent corrosion resistance and a smooth finish, while extending the overall service life of the product.
Clean Inner Wall: Adopting an automatic forming process, the inner wall of copper tubes is kept dry, clean and free of impurities to ensure stable operating performance.
Air Tightness Test: All products pass a 2.6MPa air tightness test, fully complying with strict air tightness standard requirements.
Efficient Heat Transfer: Aluminum fins and copper tubes are tightly integrated via hydraulic expansion processing, realizing consistent and efficient heat transfer performance with superior stability.
Branded Components: Equipped with branded fans and heat pipes, the product features stable quality, low operating noise, low energy consumption and high operational efficiency.
Easy Installation: The slotted frame structure is specially designed to simplify on-site installation and improve assembly efficiency.
Integrated Electrics: All internal wires and plugs are centrally integrated in the electrical box, greatly facilitating daily installation, inspection and maintenance work.
Smart Defrosting: The electric defrosting system adopts high-insulation stainless steel heating tubes. With a reasonable layout design, it enables fast, high-efficiency and low-power-consumption defrosting. Users can additionally install a controller module to realize automatic defrosting control, further optimizing defrosting efficiency and reducing energy costs.
Technical Data
| MODEL | Nominal capacity (W) |
Cooling Area (m²) |
Fin Space (mm) |
Pipe diameter (mm) |
Fan | Defrost electrical heater | |||||||
| Quantity (set) |
Diameter of fans (mm) |
Air volume (m³/h) |
wind pressure (mmH₂O) |
Power(w) | Voltage(V) | Coil (kw) |
Drain water plate (kW) |
Voltage (V) |
|||||
| DJ-1.2/8 | 1200 | 8 | 9 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DJ-2.1/15 | 2100 | 15 | 9 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 2.4 | 1.2 | 220 |
| DJ3.6/20 | 3600 | 20 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-4.6/30 | 4600 | 30 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-7.1/40 | 7100 | 40 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-8.9/55 | 8900 | 55 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-11.6/70 | 11600 | 70 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-14.3/85 | 14300 | 85 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-17.1/100 | 17100 | 100 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-19.6/115 | 19600 | 115 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-22/130 | 22000 | 130 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DJ-23/140 | 23000 | 140 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-25/150 | 25000 | 150 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-28/170 | 28000 | 170 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-30/190 | 30000 | 190 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-35/210 | 35000 | 210 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-41/250 | 41000 | 250 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DJ-50/300 | 50000 | 300 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DD-1.3/7 | 1300 | 7 | 6 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 1.0 | 0.5 | 220 |
| DD-2.2/12 | 2200 | 12 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DD2.8/15 | 2800 | 15 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 3x90 | 380 | 1.8 | 0.9 | 220 |
| DD-3.7/22 | 3700 | 22 | 6 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 2x90 | 380 | 2.4 | 1.2 | 220 |
| DD-5.6/30 | 5600 | 30 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-7.5/40 | 7500 | 40 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-11.2/60 | 11200 | 60 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-14.9/80 | 14900 | 80 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-18.7/100 | 18700 | 100 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-22.4/120 | 22400 | 120 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-26.4/140 | 26400 | 140 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DD-30.0/160 | 30000 | 160 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DD-35.0/180 | 35000 | 180 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DD-37.0/200 | 37000 | 200 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-40.0/220 | 40000 | 220 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-46.0/250 | 46000 | 250 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-50.0/275 | 50000 | 275 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-57.0/310 | 57000 | 310 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-67.0/360 | 67000 | 360 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DD-81.0/440 | 81000 | 440 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DL-2.0/10 | 2000 | 10 | 4.5 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 0.5 | 0.5 | 220 |
| DL-3.0/15 | 3000 | 15 | 4.5 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 0.9 | 0.9 | 220 |
| DL-5.0/25 | 5000 | 25 | 4.5 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 1.2 | 1.2 | 220 |
| DL-8.0/40 | 8000 | 40 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-11.2/55 | 11200 | 55 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-16.2/80 | 16200 | 80 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-21.0/105 | 21000 | 105 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-25.0/135 | 25000 | 135 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-32.6/160 | 32600 | 160 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-37.6/185 | 37600 | 185 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-42.7/220 | 42700 | 220 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 8.4 | 2.8 | 220 |
| DL-50.0/250 | 50000 | 250 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 9 | 3 | 220 |
| DL-55.0/280 | 55000 | 280 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-60.0/300 | 60000 | 300 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-66.0/330 | 66000 | 330 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-70.0/375 | 70000 | 375 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-82.0/410 | 82000 | 410 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-94.0/470 | 94000 | 470 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DL-116.0/580 | 11600 | 580 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
Product display
Installation Dimensions
Installation size of air cooler
| MODEL | L | D | D2 | F | E1 | N | H | Inlet | Cycle pipe | Water outlet |
| DD7/DL10 | 755 | 380 | 320 | 102.5 | 520 | 1 | 520 | 12.7 | 16 | Outer diameter: 25 |
| DD12/DL15/DJ8 | 1060 | 380 | 320 | 102.5 | 825 | 1 | 520 | 12.7 | 16 | Outer diameter: 25 |
| DD15 | 1160 | 380 | 320 | 102.5 | 925 | 1 | 520 | 12.7 | 16 | Outer diameter: 25 |
| DD20/DL25/DJ15 | 1600 | 380 | 320 | 102.5 | 1265 | 1 | 620 | 12.7 | 16 | Outer diameter: 25 |
| DD30/DL40/DJ20 | 1430 | 460 | 375 | 152.5 | 1125 | 1 | 620 | 16 | 25 | Outer diameter: 25 |
| DD40/DL55/DJ30 | 1490 | 528 | 440 | 152.5 | 1125 | 1 | 720 | 19 | 38 | G1" |
| DD60/DL80/DJ40 | 1780 | 578 | 490 | 152.5 | 737.5 | 2 | 720 | 19 | 38 | G1" |
| DD80/DL105/DJ55 | 1780 | 578 | 490 | 152.5 | 737.5 | 2 | 720 | 19 | 38 | G1" |
| DD100/DL135/DJ70 | 2230 | 643 | 555 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DD120/DL160/DJ85 | 2300 | 643 | 555 | 152.5 | 641.5 | 3 | 720 | 22 | 50 | G1" |
| DD140/DL185/DJ100 | 2920 | 578 | 490 | 152.5 | 841.5 | 3 | 720 | 22 | 50 | G1" |
| DD160/DL220/DJ115 | 2920 | 643 | 555 | 152.5 | 631 | 4 | 720 | 22 | 50 | Outer diameter: 40 |
| DD180/DL250/DJ130 | 3250 | 643 | 555 | 152.5 | 718.5 | 4 | 770 | 25 | 50 | Outer diameter: 40 |
| DD200/DL280/DJ140 | 2252 | 860 | 775 | 186 | 925 | 2 | 885 | 25 | 50 | G1.5" |
| DD220/DL300/DJ150 | 2352 | 860 | 775 | 186 | 976 | 2 | 885 | 25 | 50 | G1.5" |
| DD250/DL330/DJ170 | 2702 | 860 | 775 | 186 | 766 | 3 | 885 | 25 | 50 | G1.5" |
| DD275/DL375/DJ190 | 2902 | 860 | 775 | 186 | 833 | 3 | 885 | 25 | 50 | G1.5" |
| DD310/DL410/DJ210 | 3062 | 860 | 775 | 186 | 886 | 3 | 885 | 25 | 50 | G1.5" |
| DD360/DL470/DJ250 | 3552 | 860 | 775 | 186 | 787 | 4 | 935 | 25 | 50 | G1.5" |
| DD440/DL580/DJ300 | 3786 | 860 | 775 | 186 | 846 | 4 | 1035 | 28 | 50 | G1.5" |
Application
Frequently Asked Questions
How does the air cooler reduce noise and vibration during operation?
The panel and side plates of the air cooler feature a stepped structural design, which effectively reduces fan operating noise and vibration, ensuring a quieter and more stable operation.
What measures are taken to prevent corrosion on the equipment shell?
The equipment shell undergoes a professional phosphating treatment followed by surface spraying processes. This dual treatment delivers excellent corrosion resistance, provides a smooth finish, and extends the overall service life of the product.
What are the air tightness testing standards for these air coolers?
All units undergo and pass a strict 2.6MPa air tightness test. This ensures complete compliance with rigorous industry standards for safe and leak-free operation.
How is the defrosting system optimized for energy efficiency?
The electric defrosting system is designed with high-insulation stainless steel heating tubes placed in a highly efficient layout. This allows for fast defrosting with minimal power consumption. Additionally, users can install a controller module to automate the defrosting cycle for further energy savings.
What are the temperature parameters used to determine the DJ, DD, and DL cooling capacities?
DJ cooling capacity is calculated based on a -25℃ inlet dry-bulb temp, -31℃ evaporation temp, and 20℃ liquid temp. DD is based on -18℃ inlet, -25℃ evaporation, and 20℃ liquid temp. DL is based on 0℃ inlet, -8℃ evaporation, and 30℃ liquid temp.
Are the units easy to install and maintain on-site?
Yes. The air coolers are designed with a slotted frame structure to simplify on-site installation. For maintenance, the water pan and side plates are detachable, and all internal wires and plugs are centrally integrated inside the electrical box for easy inspection.