Contact Us
Leave Your Message
High Efficiency Evaporative Air Cooler Series - China Factory Direct HVAC Solutions from Top Suppliers
Hot Products

High Efficiency Evaporative Air Cooler Series - China Factory Direct HVAC Solutions from Top Suppliers

Introducing our innovative air cooler series, designed specifically to meet the needs of modern consumers while ensuring top performance and durability. This advanced cooling solution features an optimized step structure that significantly reduces fan noise and vibration, making it a perfect choice for any environment. Easy maintenance is guaranteed with its detachable water pan and side plates, Crafted with a corrosion-resistant shell treated by phosphating and spray coating, our air coolers promise a long service life. Each unit undergoes a rigorous 2.6MPa air tightness test, ensuring reliability. The combination of aluminum fins and copper tubes promotes efficient heat transfer, enhancing cooling effectiveness, As a leading factory in China, we pride ourselves on our commitment to quality. Our air coolers are equipped with high-performance brand fans and stainless steel electric defrosting tubes, ensuring energy savings and fast defrosting times. The thoughtful design includes a slot-type rack and an integrated electric box for straightforward installation and maintenance, For top-notch air coolers, look no further than the best suppliers in China. Experience premium cooling with our state-of-the-art air cooler series today!

    Product Features

    Low Noise & Vibration: The panel and side plates adopt a stepped structural design, which effectively reduces fan operating noise and vibration. The water pan and side plates feature a detachable structure for easy disassembly and cleaning.

    🛡️

    Corrosion Resistance: The equipment shell undergoes professional phosphating treatment and surface spraying processes, delivering excellent corrosion resistance and a smooth finish, while extending the overall service life of the product.

    💧

    Clean Inner Wall: Adopting an automatic forming process, the inner wall of copper tubes is kept dry, clean and free of impurities to ensure stable operating performance.

    🔍

    Air Tightness Test: All products pass a 2.6MPa air tightness test, fully complying with strict air tightness standard requirements.

    🔥

    Efficient Heat Transfer: Aluminum fins and copper tubes are tightly integrated via hydraulic expansion processing, realizing consistent and efficient heat transfer performance with superior stability.

    💨

    Branded Components: Equipped with branded fans and heat pipes, the product features stable quality, low operating noise, low energy consumption and high operational efficiency.

    🔧

    Easy Installation: The slotted frame structure is specially designed to simplify on-site installation and improve assembly efficiency.

    🔌

    Integrated Electrics: All internal wires and plugs are centrally integrated in the electrical box, greatly facilitating daily installation, inspection and maintenance work.

    ❄️

    Smart Defrosting: The electric defrosting system adopts high-insulation stainless steel heating tubes. With a reasonable layout design, it enables fast, high-efficiency and low-power-consumption defrosting. Users can additionally install a controller module to realize automatic defrosting control, further optimizing defrosting efficiency and reducing energy costs.

    Technical Data

    MODEL Nominal capacity
    (W)
    Cooling Area
    (m²)
    Fin Space
    (mm)
    Pipe diameter
    (mm)
    Fan Defrost electrical heater
    Quantity
    (set)
    Diameter of fans
    (mm)
    Air volume
    (m³/h)
    wind pressure
    (mmH₂O)
    Power(w) Voltage(V) Coil
    (kw)
    Drain water plate
    (kW)
    Voltage
    (V)
    DJ-1.2/8 1200 8 9 9.52 2 300 2x1700 98(10) 2x90 380 1.8 0.9 220
    DJ-2.1/15 2100 15 9 9.52 3 300 3x1700 98(10) 3x90 380 2.4 1.2 220
    DJ3.6/20 3600 20 9 16 2 400 2x4000 118(12) 2x190 380 2.6 1.3 220
    DJ-4.6/30 4600 30 9 16 2 400 2x4000 118(12) 2x190 380 2.6 1.3 220
    DJ-7.1/40 7100 40 9 16 2 500 2x6000 167(17) 2x550 380 4.5 1.5 220
    DJ-8.9/55 8900 55 9 16 2 500 2x6000 167(17) 2x550 380 4.5 1.5 220
    DJ-11.6/70 11600 70 9 16 3 500 3x6000 167(17) 3x550 380 8.4 2.1 220
    DJ-14.3/85 14300 85 9 16 3 500 3x6000 167(17) 3x550 380 8.4 2.1 220
    DJ-17.1/100 17100 100 9 16 3 500 3x6000 167(17) 3x550 380 11.2 2.8 220
    DJ-19.6/115 19600 115 9 16 4 500 4x6000 167(17) 4x550 380 11.2 2.8 220
    DJ-22/130 22000 130 9 16 4 500 4x6000 167(17) 4x550 380 12.0 3.0 380
    DJ-23/140 23000 140 9 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DJ-25/150 25000 150 9 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DJ-28/170 28000 170 9 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DJ-30/190 30000 190 9 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DJ-35/210 35000 210 9 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DJ-41/250 41000 250 9 16 4 630 4×11000 200 4×937 380 27.0 3.0 380
    DJ-50/300 50000 300 9 16 4 630 4×11000 200 4×937 380 30.0 3.0 380
    DD-1.3/7 1300 7 6 9.52 1 300 1x1700 98(10) 1x90 380 1.0 0.5 220
    DD-2.2/12 2200 12 6 9.52 2 300 2x1700 98(10) 2x90 380 1.8 0.9 220
    DD2.8/15 2800 15 6 9.52 2 300 2x1700 98(10) 3x90 380 1.8 0.9 220
    DD-3.7/22 3700 22 6 9.52 3 300 3x1700 98(10) 2x90 380 2.4 1.2 220
    DD-5.6/30 5600 30 6 16 2 400 2x4000 118(12) 2x190 380 2.6 1.3 220
    DD-7.5/40 7500 40 6 16 2 400 2x4000 118(12) 2x190 380 2.6 1.3 220
    DD-11.2/60 11200 60 6 16 2 500 2x6000 167(17) 2x550 380 4.5 1.5 220
    DD-14.9/80 14900 80 6 16 2 500 2x6000 167(17) 2x550 380 4.5 1.5 220
    DD-18.7/100 18700 100 6 16 3 500 3x6000 167(17) 3x550 380 8.4 2.1 220
    DD-22.4/120 22400 120 6 16 3 500 3x6000 167(17) 3x550 380 8.4 2.1 220
    DD-26.4/140 26400 140 6 16 3 500 3x6000 167(17) 3x550 380 11.2 2.8 220
    DD-30.0/160 30000 160 6 16 4 500 4x6000 167(17) 4x550 380 11.2 2.8 220
    DD-35.0/180 35000 180 6 16 4 500 4x6000 167(17) 4x550 380 12.0 3.0 380
    DD-37.0/200 37000 200 6 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DD-40.0/220 40000 220 6 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DD-46.0/250 46000 250 6 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DD-50.0/275 50000 275 6 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DD-57.0/310 57000 310 6 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DD-67.0/360 67000 360 6 16 4 630 4×11000 200 4×937 380 27.0 3.0 380
    DD-81.0/440 81000 440 6 16 4 630 4×11000 200 4×937 380 30.0 3.0 380
    DL-2.0/10 2000 10 4.5 9.52 1 300 1x1700 98(10) 1x90 380 0.5 0.5 220
    DL-3.0/15 3000 15 4.5 9.52 2 300 2x1700 98(10) 2x90 380 0.9 0.9 220
    DL-5.0/25 5000 25 4.5 9.52 3 300 3x1700 98(10) 3x90 380 1.2 1.2 220
    DL-8.0/40 8000 40 4.5 16 2 400 2x4000 18(12) 2x190 380 1.3 1.3 220
    DL-11.2/55 11200 55 4.5 16 2 400 2x4000 18(12) 2x190 380 1.3 1.3 220
    DL-16.2/80 16200 80 4.5 16 2 500 2x6000 167(17) 2x550 380 3 1.5 220
    DL-21.0/105 21000 105 4.5 16 2 500 2x6000 167(17) 2x550 380 3 1.5 220
    DL-25.0/135 25000 135 4.5 16 3 500 3x6000 167(17) 3x550 380 6.3 2.1 220
    DL-32.6/160 32600 160 4.5 16 3 500 3x6000 167(17) 3x550 380 6.3 2.1 220
    DL-37.6/185 37600 185 4.5 16 3 500 3x6000 167(17) 3x550 380 6.3 2.1 220
    DL-42.7/220 42700 220 4.5 16 4 500 4x6000 167(17) 4x550 380 8.4 2.8 220
    DL-50.0/250 50000 250 4.5 16 4 500 4x6000 167(17) 4x550 380 9 3 220
    DL-55.0/280 55000 280 4.5 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DL-60.0/300 60000 300 4.5 16 2 630 2×11000 200 2×937 380 24.0 3.0 380
    DL-66.0/330 66000 330 4.5 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DL-70.0/375 70000 375 4.5 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DL-82.0/410 82000 410 4.5 16 3 630 3×11000 200 3×937 380 24.0 3.0 380
    DL-94.0/470 94000 470 4.5 16 4 630 4×11000 200 4×937 380 27.0 3.0 380
    DL-116.0/580 11600 580 4.5 16 4 630 4×11000 200 4×937 380 30.0 3.0 380
    DJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
    DD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
    DL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.

    Product display

    Installation Dimensions

    Aings

    Installation size of air cooler

    MODEL L D D2 F E1 N H Inlet Cycle pipe Water outlet
    DD7/DL10 755 380 320 102.5 520 1 520 12.7 16 Outer diameter: 25
    DD12/DL15/DJ8 1060 380 320 102.5 825 1 520 12.7 16 Outer diameter: 25
    DD15 1160 380 320 102.5 925 1 520 12.7 16 Outer diameter: 25
    DD20/DL25/DJ15 1600 380 320 102.5 1265 1 620 12.7 16 Outer diameter: 25
    DD30/DL40/DJ20 1430 460 375 152.5 1125 1 620 16 25 Outer diameter: 25
    DD40/DL55/DJ30 1490 528 440 152.5 1125 1 720 19 38 G1"
    DD60/DL80/DJ40 1780 578 490 152.5 737.5 2 720 19 38 G1"
    DD80/DL105/DJ55 1780 578 490 152.5 737.5 2 720 19 38 G1"
    DD100/DL135/DJ70 2230 643 555 152.5 641.5 3 720 22 50 G1"
    DD120/DL160/DJ85 2300 643 555 152.5 641.5 3 720 22 50 G1"
    DD140/DL185/DJ100 2920 578 490 152.5 841.5 3 720 22 50 G1"
    DD160/DL220/DJ115 2920 643 555 152.5 631 4 720 22 50 Outer diameter: 40
    DD180/DL250/DJ130 3250 643 555 152.5 718.5 4 770 25 50 Outer diameter: 40
    DD200/DL280/DJ140 2252 860 775 186 925 2 885 25 50 G1.5"
    DD220/DL300/DJ150 2352 860 775 186 976 2 885 25 50 G1.5"
    DD250/DL330/DJ170 2702 860 775 186 766 3 885 25 50 G1.5"
    DD275/DL375/DJ190 2902 860 775 186 833 3 885 25 50 G1.5"
    DD310/DL410/DJ210 3062 860 775 186 886 3 885 25 50 G1.5"
    DD360/DL470/DJ250 3552 860 775 186 787 4 935 25 50 G1.5"
    DD440/DL580/DJ300 3786 860 775 186 846 4 1035 28 50 G1.5"

    Application

    Fruit and vegetable preservation cold storage Special medical cold storage Flower preservation cold storage Red wine storage cold storage Aquatic product processing and storage cold storage Special testing cold storage Food processing cold storage

    Frequently Asked Questions

    How does the air cooler reduce noise and vibration during operation?

    The panel and side plates of the air cooler feature a stepped structural design, which effectively reduces fan operating noise and vibration, ensuring a quieter and more stable operation.

    What measures are taken to prevent corrosion on the equipment shell?

    The equipment shell undergoes a professional phosphating treatment followed by surface spraying processes. This dual treatment delivers excellent corrosion resistance, provides a smooth finish, and extends the overall service life of the product.

    What are the air tightness testing standards for these air coolers?

    All units undergo and pass a strict 2.6MPa air tightness test. This ensures complete compliance with rigorous industry standards for safe and leak-free operation.

    How is the defrosting system optimized for energy efficiency?

    The electric defrosting system is designed with high-insulation stainless steel heating tubes placed in a highly efficient layout. This allows for fast defrosting with minimal power consumption. Additionally, users can install a controller module to automate the defrosting cycle for further energy savings.

    What are the temperature parameters used to determine the DJ, DD, and DL cooling capacities?

    DJ cooling capacity is calculated based on a -25℃ inlet dry-bulb temp, -31℃ evaporation temp, and 20℃ liquid temp. DD is based on -18℃ inlet, -25℃ evaporation, and 20℃ liquid temp. DL is based on 0℃ inlet, -8℃ evaporation, and 30℃ liquid temp.

    Are the units easy to install and maintain on-site?

    Yes. The air coolers are designed with a slotted frame structure to simplify on-site installation. For maintenance, the water pan and side plates are detachable, and all internal wires and plugs are centrally integrated inside the electrical box for easy inspection.