China Air Cooler Series - High Efficiency, Low Noise, Automatic Defrosting | Trusted Suppliers and Factory
Product Features
1
Panel and side plates are well constructed by using step structure, reducing the noise caused by fan and fan vibration. Water pan and side plate are easy to dismantle.
2
After treatment of phosphating and surface spray, the shell becomes corrosion resistance, smooth and achieves a longer life span.
3
Automatic molding process ensures dry and clean interior of the copper tube.
4
2.6mpa air tightness test satisfies product air tightness requirements.
5
Expanded by liquid pressure machine, the aluminum fin and copper tube are combined tightly and achieves a stable effect of heat transfer.
6
Famous brand fan and heat tube achieves stable quality, low noise, less energy consumption and high efficiency.
7
Slot type rack design convenient for installation.
8
All wires and plugs are connected in an electrical box, convenient for installation and maintenance.
9
Electric defrosting selects high insulation performance stainless steel heating tube. Reasonable distribution achieves short time defrost, high efficiency and low consumption. Users can add module in the controller to realize the automatic defrosting control. Fast efficient defrosting and less energy cost.
Technical Data
| MODEL | Nominal capacity (W) |
Cooling Area (m²) |
Fin Space (mm) |
Pipe diameter (mm) |
Fan | Defrost electrical heater | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Qty (set) |
Dia. (mm) |
Air vol. (m³/h) |
Press. (mmH₂O) |
Power (W) |
Volt. (V) |
Coil (kW) |
Drain (kW) |
Volt. (V) |
|||||
| DJ-1.2/8 | 1200 | 8 | 9 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DJ-2.1/15 | 2100 | 15 | 9 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 2.4 | 1.2 | 220 |
| DJ3.6/20 | 3600 | 20 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-4.6/30 | 4600 | 30 | 9 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DJ-7.1/40 | 7100 | 40 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-8.9/55 | 8900 | 55 | 9 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DJ-11.6/70 | 11600 | 70 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-14.3/85 | 14300 | 85 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DJ-17.1/100 | 17100 | 100 | 9 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-19.6/115 | 19600 | 115 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DJ-22/130 | 22000 | 130 | 9 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DJ-23/140 | 23000 | 140 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-25/150 | 25000 | 150 | 9 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-28/170 | 28000 | 170 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-30/190 | 30000 | 190 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-35/210 | 35000 | 210 | 9 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DJ-41/250 | 41000 | 250 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DJ-50/300 | 50000 | 300 | 9 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DD-1.3/7 | 1300 | 7 | 6 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 1.0 | 0.5 | 220 |
| DD-2.2/12 | 2200 | 12 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 1.8 | 0.9 | 220 |
| DD2.8/15 | 2800 | 15 | 6 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 3x90 | 380 | 1.8 | 0.9 | 220 |
| DD-3.7/22 | 3700 | 22 | 6 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 2x90 | 380 | 2.4 | 1.2 | 220 |
| DD-5.6/30 | 5600 | 30 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-7.5/40 | 7500 | 40 | 6 | 16 | 2 | 400 | 2x4000 | 118(12) | 2x190 | 380 | 2.6 | 1.3 | 220 |
| DD-11.2/60 | 11200 | 60 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-14.9/80 | 14900 | 80 | 6 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 4.5 | 1.5 | 220 |
| DD-18.7/100 | 18700 | 100 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-22.4/120 | 22400 | 120 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 8.4 | 2.1 | 220 |
| DD-26.4/140 | 26400 | 140 | 6 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 11.2 | 2.8 | 220 |
| DD-30.0/160 | 30000 | 160 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 11.2 | 2.8 | 220 |
| DD-35.0/180 | 35000 | 180 | 6 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 12.0 | 3.0 | 380 |
| DD-37.0/200 | 37000 | 200 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-40.0/220 | 40000 | 220 | 6 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DD-46.0/250 | 46000 | 250 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-50.0/275 | 50000 | 275 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-57.0/310 | 57000 | 310 | 6 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DD-67.0/360 | 67000 | 360 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DD-81.0/440 | 81000 | 440 | 6 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
| DL-2.0/10 | 2000 | 10 | 4.5 | 9.52 | 1 | 300 | 1x1700 | 98(10) | 1x90 | 380 | 0.5 | 0.5 | 220 |
| DL-3.0/15 | 3000 | 15 | 4.5 | 9.52 | 2 | 300 | 2x1700 | 98(10) | 2x90 | 380 | 0.9 | 0.9 | 220 |
| DL-5.0/25 | 5000 | 25 | 4.5 | 9.52 | 3 | 300 | 3x1700 | 98(10) | 3x90 | 380 | 1.2 | 1.2 | 220 |
| DL-8.0/40 | 8000 | 40 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-11.2/55 | 11200 | 55 | 4.5 | 16 | 2 | 400 | 2x4000 | 18(12) | 2x190 | 380 | 1.3 | 1.3 | 220 |
| DL-16.2/80 | 16200 | 80 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-21.0/105 | 21000 | 105 | 4.5 | 16 | 2 | 500 | 2x6000 | 167(17) | 2x550 | 380 | 3 | 1.5 | 220 |
| DL-25.0/135 | 25000 | 135 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-32.6/160 | 32600 | 160 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-37.6/185 | 37600 | 185 | 4.5 | 16 | 3 | 500 | 3x6000 | 167(17) | 3x550 | 380 | 6.3 | 2.1 | 220 |
| DL-42.7/220 | 42700 | 220 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 8.4 | 2.8 | 220 |
| DL-50.0/250 | 50000 | 250 | 4.5 | 16 | 4 | 500 | 4x6000 | 167(17) | 4x550 | 380 | 9 | 3 | 220 |
| DL-55.0/280 | 55000 | 280 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-60.0/300 | 60000 | 300 | 4.5 | 16 | 2 | 630 | 2×11000 | 200 | 2×937 | 380 | 24.0 | 3.0 | 380 |
| DL-66.0/330 | 66000 | 330 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-70.0/375 | 70000 | 375 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-82.0/410 | 82000 | 410 | 4.5 | 16 | 3 | 630 | 3×11000 | 200 | 3×937 | 380 | 24.0 | 3.0 | 380 |
| DL-94.0/470 | 94000 | 470 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 27.0 | 3.0 | 380 |
| DL-116.0/580 | 11600 | 580 | 4.5 | 16 | 4 | 630 | 4×11000 | 200 | 4×937 | 380 | 30.0 | 3.0 | 380 |
SDJ Cooling Capacity: Based on an air inlet dry-bulb temperature of -25℃, evaporation temperature of -31℃, and refrigerant liquid temperature of 20℃.
SDD Cooling Capacity: Based on an air inlet dry-bulb temperature of -18℃, evaporation temperature of -25℃, and refrigerant liquid temperature of 20℃.
SDL Cooling Capacity: Based on an air inlet dry-bulb temperature of 0℃, evaporation temperature of -8℃, and refrigerant liquid temperature of 30℃.
Product display
Installation Dimensions
Installation size of air cooler
| MODEL | L | D | D2 | F | E1 | N | H | Inlet | Cycle pipe | Inlet port | Water outlet |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DL25/DD22/DJ15 | 1580 | 475 | 430 | 100 | 1380 | 1 | 604 | 12.7 | 19 | G1.5*1 | G2.5" |
| DL40/DD30/DJ20 | 1430 | 550 | 460 | 150 | 1130 | 1 | 704 | 16 | 25 | G1.5*1 | G2.5" |
| DL55/DD40/DJ30 | 1430 | 600 | 510 | 150 | 1130 | 1 | 704 | 16 | 25 | G1.5*1 | G2.5" |
| DL80/DD60/DJ40 | 1780 | 617.5 | 545 | 150 | 740 | 2 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL105/DD80/DJ55 | 1780 | 667.5 | 595 | 150 | 740 | 2 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL135/DD100/DJ70 | 2230 | 667.5 | 595 | 150 | 643 | 3 | 804 | 19 | 38 | G1.5*1 | G2.5" |
| DL160/DD120/DJ85 | 2230 | 712.5 | 635 | 150 | 643 | 3 | 804 | 19 | 42 | G1.5*1 | G2.5" |
| DL185/DD140/DJ100 | 2830 | 667.5 | 595 | 150 | 643 | 3 | 804 | 22 | 50 | G1.5*1 | G2.5" |
| DL220/DD160/DJ115 | 2830 | 712.5 | 635 | 150 | 632.5 | 4 | 804 | 25 | 50 | G1.5*2 | G3" |
| DL250/DD180/DJ130 | 3180 | 712.5 | 635 | 150 | 720 | 4 | 804 | 25 | 50 | G1.5*2 | G4" |
| DL280/DD200/DJ140 | 2252 | 860 | 775 | 186 | 925 | 2 | 1032 | 25 | 50 | G1.5" | G3" |
| DL300/DD220/DJ150 | 2352 | 860 | 775 | 186 | 976 | 2 | 1032 | 25 | 50 | G1.5" | G3" |
| DL330/DD250/DJ170 | 2702 | 860 | 775 | 186 | 766 | 3 | 1032 | 25 | 50 | G1.5" | G3" |
| DL375/DD275/DJ190 | 2902 | 860 | 775 | 186 | 833 | 3 | 1032 | 25 | 50 | G1.5" | G4" |
| DL410/DD310/DJ210 | 3062 | 860 | 775 | 186 | 886 | 3 | 1032 | 25 | 50 | G1.5" | G4" |
| DL470/DD360/DJ250 | 3552 | 860 | 775 | 186 | 787 | 4 | 1082 | 25 | 50 | G1.5" | G4" |
| DL580/DD440/DJ300 | 3786 | 860 | 775 | 186 | 846 | 4 | 1182 | 28 | 50 | G1.5" | G4" |
Application
Frequently Asked Questions
Q: How does the air cooler reduce operation noise and vibration?
A: The panel and side plates are engineered using a step structure. This specific layout effectively minimizes the vibration caused by the fan, resulting in lower operational noise. Additionally, both the water pan and side plates are designed for easy dismantling.
Q: What treatment is applied to the shell to ensure durability?
A: The shell undergoes a thorough phosphating treatment followed by a surface spray coating. This process provides excellent corrosion resistance, a smooth surface finish, and a significantly extended product life span.
Q: How is the air tightness of the air cooler guaranteed?
A: Every unit is subjected to a strict 2.6MPa air tightness test during manufacturing to ensure it meets all structural and operational air tightness requirements.
Q: What type of defrosting system is used in these units?
A: The units utilize electric defrosting with high-insulation stainless steel heating tubes. Their optimized layout ensures short defrost times, high efficiency, and low energy consumption. Users can also integrate an automatic defrosting controller module.
Q: What are the standard test conditions for SDJ, SDD, and SDL cooling capacities?
A: SDJ capacity is tested at -25℃ inlet / -31℃ evaporation; SDD at -18℃ inlet / -25℃ evaporation; and SDL at 0℃ inlet / -8℃ evaporation. All capacities are calculated with a refrigerant liquid temperature of 20℃ (30℃ for SDL).
Q: What cold storage applications are these air coolers suitable for?
A: They are highly suitable for fruit & vegetable preservation, medical cold storage, flower preservation, red wine storage, aquatic product processing, special testing facilities, and food processing cold storage.